Co2 Fractional Laser for Skin Resurfacing Vaginal Tightening

Model:CO2

Systems:Fractional system, Cutting system, Vaginal system optional

Emitter:US Coherent RF metal tube

Logo:Free logo service to machine software

Description:Co2 Fractional Laser is medical device used for Skin Resurfacing and Vaginal Tightening. With metal RF tube we gurantee at least 45000 hours use about 10 years. Get the factory price from TEC DIODE company.


Co2 Fractional Laser for Skin Resurfacing Vaginal Tightening 






Highlights

Co2 Fractional Laser for Skin Resurfacing Vaginal Tightening with below highlights:

  • US Coherent RF metal tube, much longer lifespan

  • 3 Systems cover all functions.

  • 14 Graphics for all areas treatment.




Working Theory

Fractional Skin Resurfacing Working Theory

Co2 Fractional Laser for Skin Resurfacing Vaginal Tightening Working theory

The new developed RF CO2 fractional laser fires a laser beam through RF CO2 tube which is split into numbers of microscopic beam, producing tinier dot than general CO2 laser (glass tube). The treatment tip can vaporize the outmost layers of the skin across a large surface by creating thousands of tiny, microscopic laser wounds, spaced in an even pattern across the skin, but leaving areas of healthy, untreated skin between them, the lower collagen layer of the dermis is stimulated to renew and repair. Therefore, the heat of laser only passes deeply through the factional damaged area, the surface of skin now contains only microscopic surface wounds, in stead of a large, red, oozing burn. During the skin self-resurfacing, a great amount of collagen is produced for skin rejuvenation, after some recovery, the newly-generated skin is remarkably smoother, healthier.



Vaginal Tightening Working Theory

Co2 Fractional Laser for Vaginal Tightening principle

Vaginal tightening laser is the use of water uptake 10600nm gold standard laser, using a three-dimensional lattice technology and 360-degree circular emission perfect combination of technology, to produce 50-70 degrees Celsius in a controlled depth of the vaginal mucosa, stimulate lamina propria and myometrium newborn fibroblasts, and damaged collagen fibers, elastic fibers, such as restructuring, so as to achieve vaginal wall thickening and tighteningof the vagina so that firmness, sensitivity enhancement, vagina tight as ever.




Display

Co2 Fractional Laser for Skin Resurfacing Vaginal Tightening

Standard color is white grey. For other colors also can customize for free(Above photo is our customized grey pink for client)




Specification

Product NameCo2 Fractional Laser for Skin Resurfacing Vaginal Tightening
Laser typeUSA Coherent laser (RF Tube, lifetime 5-10 years)
Wavelength10600nm
SystemsFractional and cutting system standard; Vaginal system optional
Output Power1-40W
Input Power600W
Output GraphicsStandard Triangles, Rectangles, Circles, Hexagons. Totally 14 graphics available.
Light guiding system7 joints,360° rotation
Scanning modeSequence, Random scanning
Spot size0.08-0.12mm
Scan areaUp to 20*20mm
Aiming beam650nm red diode laser, laser power 0.1-5mW
Net Weight48kg
Gross Weight58kg
Volume Weight100kg
Packing Size136*54*68cm


Details

Co2 Fractional Laser for Skin Resurfacing Vaginal Tightening inner parts

High Quality Parts

  • Strong and beautiful ABS shell, with iron stand inside machine

  • Unique extra water filters design, greatly prolong the lifespan of the machine

  • 2 thickest aluminum radiators plus 4 big fans

  • 8L big acrylic water tank, transparent and strong.

  • Latest brushless DC water pump, with high lift to 15 meters. Compare with the outdated magnetic drive pump, the brushless DC pump we use has much lower noise and much higher water flow speed. High water flow speed means it can take away the heat very quickly and protect the machine.

  • 12 inch big LED screen


RF Metal Laser Tube from US Coherent.

In market there are 2 types of CO2 emitter, glass tube and RF laser tube. We usd 40W RF Metal tube from US Coherent, ensure powerful and stable energy.


Why choose metal tube instead of glass tube?
Our RF tube life can reach more than 45,000 hours, generally can be used for at least 6 years, inflatable can be reused, no need to replace; while glass tube is only 8000-10000 hours, usually need to replace the glass tube for half a year, can not be repeated use.





undefined

7 Joints 360° Rotation Light Guiding Arm

Korean imported 7 Joints 360° Rotation Light Guiding Arm, output energy is more stable , smallest energy reduction.




Fractional SystemCutting SystemGynecology System
Reduces various scars (hypertrophic scars, depressed scars, bums, operation scars etc). Reduces seborrhetic keratosis, age pigment, freckle, wrinkle, and uneven holes, skin rejuvenation.
CO2 laser removes skin layers by vaporization. Removal age spot, sun spot by cutting.
After treatment, the skin will totally be smooth than ever.
Automatically 360°rotation. Automatically treats the vaginal sickness, easy operation with precise scale, computer control the depth and speed.


14 Graphics

14 variable treatment graphics, adjustable shapes, sizes and spacing for different area treatments.



Interface

Easy Interface

undefined

This machine has very easy use interface. You can put any treatment tip to the handle, the handle will intelligent recoginize which tip it is and automatically offer the preset parameters for the treatment.

Machine has installed 15 main languages to meet worldwide clients' demand. And meantime it has 4 systems which makes it very easy to use and maintainance. The systems are: alarming system, monitoring system, record saving system and renting system.




Treatment Range

Fractional CO2 Laser is widely used in the treatment of dermatology, gynecology, general surgery, ENT and anorectal etc. It has minimal side effects and no down time. Only thermal shocks to tiny area of the skin, little pain, no bleeding.


1- Skin resurfacing (Rough skin, coarse pores, dark skin, light damage…) 2- Wrinkles (Crow's feet, head lines, Sichuan characters, Decree lines) 3- Pigmented nevus, epidermal pigmentation (freckles, etc.), epidermis (all kinds of warts) cutting 4- Scar Repair (acne scar, hypertrophic scar, burn scar, sunken scar, etc.) 5- Other applications (syringoma, condyloma, seborrheic, etc.) 6- Viginal care (Vaginal wall tightening, collagen remodeling, thicker and more resilient, labium whitening)



FAQ

Do you offer training?
- Yes, we offer in-site, online, video training for all our Co2 Fractional Laser for Skin Resurfacing Vaginal Tightening.

What’s the warranty?
- 1 years free warranty and lifetime free after-sales service is offered for all Co2 Fractional Laser for Skin Resurfacing Vaginal Tightening.

How long can I get the machine?
- After payment, we need 5 days for production and testing, shipping takes 7-9 days, Totally after 2 weeks you can get it at your door.

Can you put my logo to machine?
- Yes we offer free logo service for all our models. We can put your logo to machine software and machine shell. It is free service






Pre:No Data Next:No Data